portant; font-family: 微软雅黑; white-space: normal; orphans: 2; float: none; color: rgb(51,51,51); font-size: 13px; font-weight: normal; word-spacing: 0px; font-variant-ligatures: normal; font-variant-caps: normal; -webkit-text-stroke-width: 0px; text-decoration-style: initial; text-decoration-color: initial"> 消防泵安装的好坏决定着泵体工作时流量及压力是否能达到,每个安装都需要图纸,以及提前考察安装场地。按照规定的过程逐一安装:
消防泵安装图
portant; font-family: 微软雅黑; white-space: normal; orphans: 2; float: none; color: rgb(51,51,51); font-size: 13px; font-weight: normal; word-spacing: 0px; font-variant-ligatures: normal; font-variant-caps: normal; -webkit-text-stroke-width: 0px; text-decoration-style: initial; text-decoration-color: initial"> 安装流程:
portant; font-family: 微软雅黑; white-space: normal; orphans: 2; float: none; color: rgb(51,51,51); font-size: 13px; font-weight: normal; word-spacing: 0px; font-variant-ligatures: normal; font-variant-caps: normal; -webkit-text-stroke-width: 0px; text-decoration-style: initial; text-decoration-color: initial"> ①安装前检查消防泵的完好情况。
portant; font-family: 微软雅黑; white-space: normal; orphans: 2; float: none; color: rgb(51,51,51); font-size: 13px; font-weight: normal; word-spacing: 0px; font-variant-ligatures: normal; font-variant-caps: normal; -webkit-text-stroke-width: 0px; text-decoration-style: initial; text-decoration-color: initial"> ②消防泵安装位置应尽可能靠近水源处。
portant; font-family: 微软雅黑; white-space: normal; orphans: 2; float: none; color: rgb(51,51,51); font-size: 13px; font-weight: normal; word-spacing: 0px; font-variant-ligatures: normal; font-variant-caps: normal; -webkit-text-stroke-width: 0px; text-decoration-style: initial; text-decoration-color: initial"> ③消防泵与底座安装有两种方式,一种是直接装在水泥基础上的刚性连接,另一种是采用JGD型减振器安装的柔性连接。
portant; font-family: 微软雅黑; white-space: normal; orphans: 2; float: none; color: rgb(51,51,51); font-size: 13px; font-weight: normal; word-spacing: 0px; font-variant-ligatures: normal; font-variant-caps: normal; -webkit-text-stroke-width: 0px; text-decoration-style: initial; text-decoration-color: initial"> ④直接安装可将消防泵安放基础上垫高30-40毫米(准备充填水泥浆之用,然后进行校正,并穿好地脚螺栓,充填水泥砂浆,经3~5天水泥干涸后,重新校正,待水泥完全干涸后,拧紧地脚螺栓的螺母。
portant; font-family: 微软雅黑; white-space: normal; orphans: 2; float: none; color: rgb(51,51,51); font-size: 13px; font-weight: normal; word-spacing: 0px; font-variant-ligatures: normal; font-variant-caps: normal; -webkit-text-stroke-width: 0px; text-decoration-style: initial; text-decoration-color: initial"> ⑤安装管路时,进、出水管路都应有各自的支承,不应使消防泵的法兰承受过大的管路重量。
portant; font-family: 微软雅黑; white-space: normal; orphans: 2; float: none; color: rgb(51,51,51); font-size: 13px; font-weight: normal; word-spacing: 0px; font-variant-ligatures: normal; font-variant-caps: normal; -webkit-text-stroke-width: 0px; text-decoration-style: initial; text-decoration-color: initial"> ⑥消防泵用于有吸程场合,进水管端应装有底阀,并且进出口管路不应有过多弯道,同时不得有漏水、漏气现象存在。
portant; font-family: 微软雅黑; white-space: normal; orphans: 2; float: none; color: rgb(51,51,51); font-size: 13px; font-weight: normal; word-spacing: 0px; font-variant-ligatures: normal; font-variant-caps: normal; -webkit-text-stroke-width: 0px; text-decoration-style: initial; text-decoration-color: initial"> ⑦在进口管路上最好装有过滤网,以防杂质进入叶轮内部。滤网的有效面积应是进水管面积的3~4倍,以保证液体的自由畅通。
portant; font-family: 微软雅黑; white-space: normal; orphans: 2; float: none; color: rgb(51,51,51); font-size: 13px; font-weight: normal; word-spacing: 0px; font-variant-ligatures: normal; font-variant-caps: normal; -webkit-text-stroke-width: 0px; text-decoration-style: initial; text-decoration-color: initial"> ⑧为了维护和使用方便安全,在消防泵的进、出口管路上各装有一只调节阀及消防泵出口附近安装一只压力表,以保证在额定范围内运行,确保消防泵的正常运行和使用寿命。
portant; font-family: 微软雅黑; white-space: normal; orphans: 2; float: none; color: rgb(51,51,51); font-size: 13px; font-weight: normal; word-spacing: 0px; font-variant-ligatures: normal; font-variant-caps: normal; -webkit-text-stroke-width: 0px; text-decoration-style: initial; text-decoration-color: initial"> ⑨进口如需扩径连接,请选用偏心异径管道接头。
portant; font-family: 微软雅黑; white-space: normal; orphans: 2; float: none; color: rgb(51,51,51); font-size: 13px; font-weight: normal; word-spacing: 0px; font-variant-ligatures: normal; font-variant-caps: normal; -webkit-text-stroke-width: 0px; text-decoration-style: initial; text-decoration-color: initial"> 消防泵安装完成后,一定要进行校正,多次试运转后无异常,才算合格,同时也要满足低流量运转要求。根据具体工况做出合理的设计。章摘自:http://www.boquanpumps.com/
联系人:孙总
手机:13906439099